1.
J Am Heart Assoc ; 6(8)2017 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-28862942

RESUMEN

BACKGROUND: Characterization of myocardial health by bipolar electrograms are critical for ventricular tachycardia therapy. Dependence of bipolar electrograms on electrode orientation may reduce reliability of voltage assessment along the plane of arrhythmic myocardial substrate. Hence, we sought to evaluate voltage assessment from orientation-independent omnipolar electrograms. METHODS AND RESULTS: We mapped the ventricular epicardium of 5 isolated hearts from each species-healthy rabbits, healthy pigs, and diseased humans-under paced conditions. We derived bipolar electrograms and voltage peak-to-peak (Vpps) along 2 bipolar electrode orientations (horizontal and vertical). We derived omnipolar electrograms and Vpps using omnipolar electrogram methodology. Voltage maps were created for both bipoles and omnipole. Electrode orientation affects the bipolar voltage map with an average absolute difference between horizontal and vertical of 0.25±0.18 mV in humans. Vpps provide larger absolute values than horizontal and vertical bipolar Vpps by 1.6 and 1.4 mV, respectively, in humans. Bipolar electrograms with the largest Vpps from either along horizontal or vertical orientation are highly correlated with omnipolar electrograms and with Vpps values (0.97±0.08 and 0.94±0.08, respectively). Vpps values are more consistent than bipoles, in both beat-by-beat (CoV, 0.28±0.19 versus 0.08±0.13 in human hearts) and rhythm changes (0.55±0.21 versus 0.40±0.20 in porcine hearts). CONCLUSIONS: Omnipoles provide physiologically relevant and consistent voltages that are along the maximal bipolar direction on the plane of the myocardium.


Asunto(s)
Potenciales de Acción , Técnicas Electrofisiológicas Cardíacas , Frecuencia Cardíaca , Corazón/fisiología , Taquicardia Ventricular/diagnóstico , Función Ventricular , Animales , Estimulación Cardíaca Artificial , Ablación por Catéter , Cricetinae , Humanos , Preparación de Corazón Aislado , Masculino , Valor Predictivo de las Pruebas , Procesamiento de Señales Asistido por Computador , Sus scrofa , Taquicardia Ventricular/fisiopatología , Factores de Tiempo
2.
Artículo en Inglés | MEDLINE | ID: mdl-28314848

RESUMEN

BACKGROUND: After defibrillation of initial ventricular fibrillation (VF), it is crucial to prevent refibrillation to ensure successful resuscitation outcomes. Inability of the late Na+ current to inactivate leads to intracellular Ca2+ dysregulation and arrhythmias. Our aim was to determine the effects of ranolazine and GS-967, inhibitors of the late Na+ current, on ventricular refibrillation. METHODS AND RESULTS: Long-duration VF was induced electrically in Langendorff-perfused rabbit hearts (n=22) and terminated with a defibrillator after 6 minutes. Fibrillating hearts were randomized into 3 groups: treatment with ranolazine, GS-967, or nontreated controls. In the treated groups, hearts were perfused with ranolazine or GS-967 at 2 minutes of VF. In control experiments, perfusion solution was supplemented with isotonic saline in lieu of a drug. Inducibility of refibrillation was assessed after initial long-duration VF by attempting to reinduce VF. Sustained refibrillation was successful in fewer ranolazine-treated (29.17%; P=0.005) or GS-967-treated (45.83%, P=0.035) hearts compared with that in nontreated control hearts (84.85%). In GS-967-treated hearts, significantly more spontaneous termination of initial long-duration VF was observed (66.67%; P=0.01). Ca2+ transient duration was reduced in ranolazine-treated hearts compared with that in controls (P=0.05) and also Ca2+ alternans (P=0.03). CONCLUSIONS: Late Na+ current inhibition during long-duration VF reduces the susceptibility to subsequent refibrillation, partially by mitigating dysregulation of intracellular Ca2+. These results suggest the potential therapeutic use of ranolazine and GS-967 and call for further testing in cardiac arrest models.


Asunto(s)
Canales de Calcio/efectos de los fármacos , Calcio/metabolismo , Cardioversión Eléctrica/métodos , Ranolazina/farmacología , Canales de Sodio/efectos de los fármacos , Fibrilación Ventricular/terapia , Animales , Canales de Calcio/metabolismo , Modelos Animales de Enfermedad , Paro Cardíaco/terapia , Modelos Logísticos , Piridinas/farmacología , Conejos , Distribución Aleatoria , Valores de Referencia , Bloqueadores de los Canales de Sodio/farmacología , Canales de Sodio/metabolismo , Estadísticas no Paramétricas , Triazoles/farmacología , Fibrilación Ventricular/diagnóstico
3.
Heart Rhythm ; 14(4): 608-615, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-28104480

RESUMEN

BACKGROUND: Endocardial mapping tools use variable interelectrode resolution, whereas body surface mapping tools use narrow bandpass filtering (BPF) to map fibrillatory mechanisms established by high-resolution optical imaging. OBJECTIVE: The purpose of this study was to study the effect of resolution and BPF on the underlying mechanism being mapped. METHODS: Hearts from 14 healthy New Zealand white rabbits were Langendorff perfused. We studied the effect of spatial resolution and BPF on the location and characterization of rotors by comparing phase singularities detected by high-resolution unfiltered optical maps and of fibrillating myocardium with decimated and filtered maps with simulated electrode spacing of 2, 5, and 8 mm. RESULTS: As we decimated the maps with 2-mm, 5-mm, and 8-mm interelectrode spacing, the mean ( ± SD) number of rotors detected decreased from 10.2 ± 9.6, 1.6 ± 3.2, and 0.2 ± 0.5, respectively. Lowering the resolution led to synthesized pseudo-rotors that may be inappropriately identified. Applying a BPF led to fewer mean phase singularities detected (248 ± 207 vs 333 ± 130; P<.01), giving the appearance of pseudo-spatial stability measured as translation index (with BPF 3.6 ± 0.4 mm vs 4.0 ± 0.5 mm without BPF; P<.01) and pseudo-temporal stability with longer duration (70.0 ± 17.6 ms in BPF maps vs 44.1 ± 6.6 ms in unfiltered maps; P<.001) than true underlying fibrillating myocardium mapped. CONCLUSION: Electrode resolution and BPF of electrograms can result in distortion of the underlying electrophysiology of fibrillation. Newer mapping techniques need to demonstrate sensitivity analysis to quantify the degree of distortion before clinical use to avoid inaccurate electrophysiologic interpretation.


Asunto(s)
Fibrilación Atrial , Técnicas Electrofisiológicas Cardíacas/métodos , Fibrilación Ventricular , Imagen de Colorante Sensible al Voltaje/métodos , Animales , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Mapeo del Potencial de Superficie Corporal/métodos , Modelos Animales de Enfermedad , Modelos Cardiovasculares , Conejos , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/fisiopatología
4.
Circ Arrhythm Electrophysiol ; 8(6): 1433-42, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26480929

RESUMEN

BACKGROUND: Substrate-based mapping for ventricular tachycardia (VT) ablation is hampered by its inability to determine critical sites of the VT circuit. We hypothesized that those potentials, which delay with a decremental extrastimulus (decrement evoked potentials or DEEPs), are more likely to colocalize with the diastolic pathways of VT circuits. METHODS AND RESULTS: DEEPs were identified in intraoperative left ventricular maps from 6 patients with ischemic cardiomyopathy (total 9 VTs) and were compared with late potential (LP) and activation maps of the diastolic pathway for each VT. Mathematical modeling was also used to further validate and elucidate the mechanisms of DEEP mapping. All patients demonstrated regions of DEEPs and LPs. The mean endocardial surface area of these potentials was 18±4% and 21±6%, respectively (P=0.13). The mean sensitivity for identifying the diastolic pathway in VT was 50±23% for DEEPs and 36±32% for LPs (P=0.31). The mean specificity was 43±23% versus 20±8% for DEEP and LP mapping, respectively (P=0.031). The electrograms that displayed the greatest decrement in each case had a sensitivity and specificity for the VT isthmus of 29±10% and 95±1%, respectively. Mathematical modeling studies recapitulated DEEPs at the VT isthmus and demonstrated their role in VT initiation with a critical degree of decrement. CONCLUSIONS: In this preliminary study, DEEP mapping was more specific than LP mapping for identifying the critical targets of VT ablation. The mechanism of DEEPs relates to conduction velocity restitution magnified by zigzag conduction within scar channels.


Asunto(s)
Ablación por Catéter/métodos , Técnicas Electrofisiológicas Cardíacas , Potenciales Evocados , Sistema de Conducción Cardíaco/cirugía , Ventrículos Cardíacos/cirugía , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Estimulación Cardíaca Artificial , Sistema de Conducción Cardíaco/fisiopatología , Ventrículos Cardíacos/fisiopatología , Humanos , Cuidados Intraoperatorios , Masculino , Modelos Cardiovasculares , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Estudios Retrospectivos , Procesamiento de Señales Asistido por Computador , Taquicardia Ventricular/fisiopatología
5.
Europace ; 16(11): 1684-8, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24554525

RESUMEN

AIMS: Current conventional ablation strategies for ventricular tachycardia (VT) aim to interrupt reentrant circuits by creating ablation lesions. However, the critical components of reentrant VT circuits may be located at deep intramural sites. We hypothesized that bipolar ablations would create deeper lesions than unipolar ablation in human hearts. METHODS AND RESULTS: Ablation was performed on nine explanted human hearts at the time of transplantation. Following explant, the hearts were perfused by using a Langendorff perfusion setup. For bipolar ablation, the endocardial catheter was connected to the generator as the active electrode and the epicardial catheter as the return electrode. Unipolar ablation was performed at 50 W with irrigation of 25 mL/min, with temperature limit of 50°C. Bipolar ablation was performed with the same settings. Subsequently, in a patient with an incessant septal VT, catheters were positioned on the septum from both the ventricles and radiofrequency was delivered with 40 W. In the explanted hearts, there were a total of nine unipolar ablations and four bipolar ablations. The lesion depth was greater with bipolar ablation, 14.8 vs. 6.1 mm (P < 0.01), but the width was not different (9.8 vs. 7.8 mm). All bipolar lesions achieved transmurality in contrast to the unipolar ablations. In the patient with a septal focus, bipolar ablation resulted in termination of VT with no inducible VTs. CONCLUSION: By using a bipolar ablation technique, we have demonstrated the creation of significantly deeper lesions without increasing the lesion width, compared with standard ablation. Further clinical trials are warranted to detail the risks of this technique.


Asunto(s)
Ablación por Catéter/métodos , Sistema de Conducción Cardíaco/cirugía , Taquicardia Ventricular/cirugía , Catéteres Cardíacos , Ablación por Catéter/instrumentación , Técnicas Electrofisiológicas Cardíacas , Sistema de Conducción Cardíaco/fisiopatología , Humanos , Técnicas In Vitro , Masculino , Persona de Mediana Edad , Perfusión , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología , Taquicardia Ventricular/fisiopatología , Irrigación Terapéutica , Resultado del Tratamiento